Bluetti EP760 error codes

18 codes from the official Bluetti manual (EP760 ESS), each with the manual page. For 9 of them the manual says to contact an authorized service dealer.

Applies to: Bluetti EP760.

CodeWhat it meansWhat to doServiceManual
10
Hardware LLC1 current overcurrent input
A hardware-level overcurrent on the LLC1 input. The manual lists it as a fault code without further explanation.Please contact the BLUETTI support team. dealer p. 27
26
Hardware PV1 fault
A hardware-level fault on the PV1 input. The manual lists it as a fault code without further explanation.Turn off the inverter and wait 30 minutes to restart it. If the symptom persists, please contact the BLUETTI support team. dealer p. 27
27
Hardware PV2 fault
A hardware-level fault on the PV2 input. The manual lists it as a fault code without further explanation.Turn off the inverter and wait 30 minutes to restart it. If the symptom persists, please contact the BLUETTI support team. dealer p. 27
28
Hardware PV3 fault
A hardware-level fault on the PV3 input. The manual lists it as a fault code without further explanation.Turn off the inverter and wait 30 minutes to restart it. If the symptom persists, please contact the BLUETTI support team. dealer p. 27
34
Hardware overcurrent input
A hardware-level overcurrent on the input. The manual lists it as a fault code without further explanation.Turn off the inverter and wait 30 minutes to restart it. If the symptom persists, please contact the BLUETTI support team. dealer p. 27
5
Hardware BUS overvoltage
A hardware-level overvoltage on the inverter BUS. The manual lists it as a fault code without further explanation.Please contact the BLUETTI support team. dealer p. 27
6
Hardware BUS2 overvoltage
A hardware-level overvoltage on the inverter BUS2. The manual lists it as a fault code without further explanation.Please contact the BLUETTI support team. dealer p. 27
7
Hardware battery overvoltage
A hardware-level overvoltage on the battery side. The manual lists it as a fault code without further explanation.Please contact the BLUETTI support team. dealer p. 27
8
Hardware inverter overcurrent
A hardware-level overcurrent in the inverter. The manual lists it as a fault code without further explanation.Please contact the BLUETTI support team. dealer p. 27
16
PV1 Voltage High
The voltage of the PV1 input is above the allowed limit. The solar array's total voltage is too high for the inverter.Check if the total voltage of solar panels exceeds the limit. Reduce the number of solar panels, and the inverter resumes operation after calibration. owner p. 72
17
PV2 Voltage High
The voltage of the PV2 input is above the allowed limit. The solar array's total voltage is too high for the inverter.Check if the total voltage of solar panels exceeds the limit. Reduce the number of solar panels, and the inverter resumes operation after calibration. owner p. 72
18
PV3 Voltage High
The voltage of the PV3 input is above the allowed limit. The solar array's total voltage is too high for the inverter.Check if the total voltage of solar panels exceeds the limit. Reduce the number of solar panels, and the inverter resumes operation after calibration. owner p. 72
19
PV1 ISO Failure
An insulation fault on the PV1 array. The manual associates it with a possible short between the solar array and ground.Check the insulation resistor between solar array and grounding for a short circuit. owner p. 72
20
PV2 ISO Failure
An insulation fault on the PV2 array. The manual associates it with a possible short between the solar array and ground.Check the insulation resistor between solar array and grounding for a short circuit. owner p. 72
21
PV3 ISO Failure
An insulation fault on the PV3 array. The manual associates it with a possible short between the solar array and ground.Check the insulation resistor between solar array and grounding for a short circuit. owner p. 72
32
Fan Failure
The inverter cooling fan is not working correctly.Check if the inverter fan operates well. owner p. 73
35
DC Input Voltage Low
The DC input voltage is too low for normal operation.Check if the DC voltage is too low. owner p. 73
36
DC Input Voltage High
The DC input voltage does not match the battery specifications.Check if the DC voltage is inconsistent with the battery specifications. owner p. 73

Source: official Bluetti manual, read 2026-11-02. "Owner" means the manual lists steps you can take; "dealer" means it directs you to authorized service. Fuel, gas and electrical work on generators is for qualified technicians; follow the manual's safety section.