Applies to: EcoFlow DELTA 2 Max, EcoFlow DELTA Pro, EcoFlow DELTA 2.

CodeWhat it meansWhat to doServiceManual
High Temperature Charging Protection The battery is too hot, so charging is stopped to protect it.Charging resumes automatically once the battery cools down. owner p. 13
High Temperature Discharging Protection The battery is too hot, so power output is stopped to protect it.The power supply resumes automatically once the battery cools down. owner p. 13
Low Temperature Charging Protection The battery is too cold, so charging is stopped to protect it.Charging resumes automatically once battery temperature rises above 5°C (41°F). owner p. 13
Low Temperature Discharging Protection The battery is too cold, so power output is stopped to protect it.The power supply resumes automatically once battery temperature rises above -12°C (10°F). owner p. 13
AC High Temperature Protection AC output is protected because the product is overheating. The indicator flashes.Check whether the fan inlet and outlet are blocked. If not, normal operation resumes automatically after the product temperature drops. owner p. 14
AC Low Temperature Protection AC output is protected because the product is operating at too low a temperature. The indicator flashes.Use the product at optimum environmental temperatures. Normal operation resumes automatically. owner p. 14
AC Output Overload Protection AC output is protected because the connected load exceeds the rated power. The indicator flashes.Remove the overloaded device and restart the product. Use electrical appliances within rated power. owner p. 14
Battery Failure A battery fault alarm is shown on the LCD. The alarm does not clear after a restart.Stop using the product immediately and do not charge or discharge it. Contact EcoFlow Customer Service for further assistance. dealer p. 14
Car Charger High Temperature Protection The car charger output is protected because the product has overheated. The indicator flashes.Let the product cool down. It resumes normal operation automatically afterward. owner p. 14
Car Charger Overload Protection The car charger output is protected because the connected device draws too much load. The indicator flashes.Remove the device connected to the car charger. Normal operation resumes automatically. owner p. 14
Fan Blockage The fan is blocked, which may be causing the product to overheat. The indicator flashes.Check whether the fan is blocked by foreign materials and remove any obstruction. owner p. 14
High Temperature Charge Protection Charging is suspended because the battery temperature is too high. The indicator flashes.Wait for the battery to cool down. Charging resumes automatically. owner p. 14
High Temperature Discharge Protection Power supply is suspended because the battery temperature is too high. The indicator flashes.Wait for the battery to cool down. The power supply resumes automatically. owner p. 14
Low Temperature Charge Protection Charging is suspended because the battery temperature is too low. The indicator flashes.Charging resumes automatically once the battery temperature rises above 5°C (41°F). owner p. 14
Low Temperature Discharge Protection Power supply is suspended because the battery temperature is too low. The indicator flashes.The power supply resumes automatically once the battery temperature rises above -12°C (10°F). owner p. 14
USB-A Overload Protection Protection activated because the device connected to the USB-A port draws too much load. The indicator flashes.Remove the electrical device connected to the USB-A port. Normal operation resumes once it is removed. owner p. 14
USB-C High Temperature Protection Protection activated because the USB-C output has overheated. The indicator flashes.Let the product cool down. It resumes normal operation automatically afterward. owner p. 14
USB-C Overload Protection Protection activated because the device connected to the USB-C port draws too much load. The indicator flashes.Remove the electrical device connected to the USB-C port. Normal operation resumes once it is removed. owner p. 14

Source: official EcoFlow manual, read 2026-11-01. "Owner" means the manual lists steps you can take; "dealer" means it directs you to authorized service. Fuel, gas and electrical work on generators is for qualified technicians; follow the manual's safety section.