Blackout Sizer Calculator
EN
Home›Error codes›EcoFlow›RIVER 2 Pro / RIVER 2 Max

EcoFlow RIVER 2 Pro / RIVER 2 Max error codes

12 codes from the official EcoFlow manual (RIVER 2 Max), each with the manual page.

Applies to: EcoFlow RIVER 2 Pro, EcoFlow RIVER 2 Max.

CodeWhat it meansWhat to doServiceManual
AC output high temperature Indicator flashes because the product is too hot for AC output, typically from blocked airflow.Ensure the air inlet and outlet are unobstructed. Normal operation resumes automatically after the temperature decreases. If the warning persists after restart, stop using the product. owner p. 11
AC output low temperature Indicator flashes because the product is too cold for AC output.Normal operation resumes automatically when the product warms up. If the warning persists after restart, stop using the product. owner p. 11
AC output overload Indicator flashes because the AC output is overloaded.Disconnect overloading devices and restart the product. The sum power of loaded appliances must not exceed the rated power (see X-Boost section for limits in X-Boost mode). If the warning persists after restart, stop using the product. owner p. 11
Battery charging high temperature Indicator flashes because the battery is too hot for charging. Charging is paused while the battery is hot.Normal operation resumes automatically after the battery cools down. If the warning persists after restart, stop using the product. owner p. 11
Battery charging low temperature Indicator flashes because the battery is too cold for charging. Charging is paused until the battery temperature recovers.Normal operation resumes automatically after the battery temperature is restored to above 3°C. If the warning persists after restart, stop using the product. owner p. 11
Battery discharge high temperature Indicator flashes because the battery is too hot for discharging. Output is paused until the battery cools down.Normal operation resumes automatically after the battery cools down. If the warning persists after restart, stop using the product and do not charge or discharge it. owner p. 11
Battery discharge low temperature Indicator flashes because the battery is too cold for discharging. Output is paused until the battery warms up.Normal operation resumes automatically when the battery warms up. If the warning persists after restart, stop using the product and do not charge or discharge it. owner p. 11
Charging overload Indicator flashes because the charging input is overloaded.Remove the charging cable. Normal operation resumes automatically after restart. If the warning persists after restart, stop using the product. owner p. 11
Communication failure between main control board and AC Indicator flashes because the main control board and the AC section are not communicating.Normal operation resumes automatically after restart. If the warning persists after restart, stop using the product. owner p. 11
Failure of communication between main control board and AC Indicator flashes when the main control board and the AC module cannot communicate.Restart the product. Normal operation resumes automatically after restart. If the warning persists after restart, stop using the product and consult EcoFlow customer service. owner p. 11
Fan blocked Indicator flashes because the cooling fan is blocked.Check whether the fan is blocked by foreign objects and remove them. If the warning persists after restart, stop using the product. owner p. 11
USB-C or car charging output overload Indicator flashes because the USB-C or car charging output is overloaded.Disconnect overloading devices and restart the product to resume normal operation. If the warning persists after restart, stop using the product. owner p. 11

Source: official EcoFlow manual, read 2026-11-01. "Owner" means the manual lists steps you can take; "dealer" means it directs you to authorized service. Fuel, gas and electrical work on generators is for qualified technicians; follow the manual's safety section.

Size backup power for your home →