CodeWhat it meansWhat to doServiceManual
01
USB1~USB4 over current / short circuit
Over-current or short circuit on USB1 through USB4 output ports.Check whether the output port is overloaded or short-circuited. owner p. 21
02
USB-C (99W) over current / short circuit
Over-current or short circuit on the USB-C (99W) output port.Check whether the output port is overloaded or short-circuited. owner p. 21
03
USB-C (99W) (In & Out) over current / short circuit
Over-current or short circuit on the USB-C (99W) port used for input and output.Check whether the output port is overloaded or short-circuited. owner p. 21
04
DC-12V Cigarette Lighter & DC5521 over current / short circuit
Over-current or short circuit on the DC-12V cigarette lighter outlet or the DC5521 output.Check whether the output port is overloaded or short-circuited. owner p. 21
05
Inverter protection
Inverter overcurrent, overload, short-circuit, or over-voltage protection, or AC output overload in grid mode.Check whether the output port is overloaded or short-circuited. owner p. 21
06
Over-temperature protection of inverter
The inverter has overheated and its over-temperature protection has activated.Check whether the output port is overloaded or short-circuited. owner p. 21
07
Abnormal communication of battery
Communication with the battery has failed or is abnormal.Check whether the output port is overloaded or short-circuited. owner p. 21
08
EC5 input/output fault
Abnormal input voltage, output over-power, output overcurrent, over-temperature, or communication fault on the EC5 solar/car input.Check whether the input voltage meets the input range requirements. owner p. 21
09
Over-voltage protection of the system
The system has detected an over-voltage condition.Disconnect the input power source. owner p. 21
10
Under-voltage protection of the system
The system has detected an under-voltage condition.The system will automatically cut off all outputs. owner p. 21
11
Overload protection of the system / Over-temperature protection of DC module
The system is overloaded, or the DC module has overheated.Check whether the output power exceeds the maximum allowable value. Check whether expansion packs are properly mounted. owner p. 21
12
Abnormal wireless charger
The wireless charger is not operating normally.Check whether any metal objects are on the charging pad. owner p. 21
13
Abnormal AC charging
AC charging is not operating normally.Check whether the electricity power grid works properly. owner p. 21
14
Abnormal Fan status
The fan is not working or is abnormal.Check whether the fans are not working or blocked. owner p. 21
15
Abnormal Paralleling
A fault in the paralleling connection between two ZERO E units.Check whether parallel cables are properly plugged in. Check whether the output is overloaded or short-circuited. owner p. 21
16
Internal error
An internal fault has been detected in the unit.Contact Customer Service. dealer p. 21
HI
High-temperature protection of battery
The battery is too hot and high-temperature protection has activated.Check whether the unit is working in a high ambient temperature environment. owner p. 21
LO
Low-temperature protection of battery
The battery is too cold and low-temperature protection has activated.Check whether the unit is working in a cold ambient temperature environment. owner p. 21

Source: official Firman manual, read 2026-11-01. "Owner" means the manual lists steps you can take; "dealer" means it directs you to authorized service. Fuel, gas and electrical work on generators is for qualified technicians; follow the manual's safety section.