Blackout Sizer Calculator
EN
Home›Inverter & Portable Generators›A-iPower›SC2500i

A-iPower SC2500i

Generator · SC. Specs from the manufacturer page (checked ).

A-iPower SC2500i
Photo: A-iPower

The A-iPower SC2500i is a 2000 running watt, 2500 starting watt gasoline inverter generator powered by an 80cc Yamaha OHV engine. It outputs 120V AC at 60Hz and runs 9 hours at 25% load on a 1.1 gal (4.2 L) tank.

Check on Amazon →Sponsored link; we may earn a commission.
Running
2000W
Peak / surge
2500W
Fuel
gasoline
Run time @50 %
6.5h
Noise
52dB
CO shutoff
Yes
Weight
22.6kg
Warranty
3yr

Key features

What it is for

Specifications

Running watts2000 W
Peak / surge2500 W
Fuelgasoline
Tank4.2 L (1.1 gal)
Run time at 50 % load6.5 h
Noise52 dB
CO shutoffYes
AC output voltage120V
Weight22.6 kg (49.8 lb)
Dimensions57.4 × 37.5 × 55.6 cm (22.6 × 14.8 × 21.9 in)
Warranty3 years

From the A-iPower page. Values the manufacturer does not publish are left out.

Similar inverter & portable generators

A-iPower SC2500i comparisons

On our lists

Quietest portable generators (2000 W and up)

All A-iPower models →

Connection and wiring

Follow the diagrams in the A-iPower manual. Connecting to a home panel needs a transfer switch or interlock and a licensed electrician.

Open the A-iPower manual (PDF) →

Error codes and troubleshooting

CodeMeaningWhat to doManual page
Oil WarningLights when engine oil falls below the safe operating level. The generator automatically shuts off the engine and will not restart until the proper amount of oil is in the crankcase.Add the proper amount of oil to the crankcase. The engine will not start until the oil is at the proper level.10
OverloadLights when connected devices or a power surge exceed the generator's wattage or amperage capacity. The Output Ready LED turns off, the engine keeps running, and power to connected devices stops.Remove all loads and stop the engine. Check for faulty or shorted connections. Restart the generator, then reconnect devices one at a time, letting it stabilize after each. Keep total connected wattage within the rated output power.10

From the A-iPower manual. All 2 SUA2300i / XOS2600i / GXS1700i / SC2500i codes →

FAQ

How long does the A-iPower SC2500i run on a tank?

The maker rates it at 6.5 hours at 50 % load (about 1,000 W) on a 1.1-gal tank. A light load such as a refrigerator and lights runs longer; a full load runs shorter.

Can the A-iPower SC2500i start a sump pump or well pump?

Starting surge matters more than running watts: this unit is rated 2500 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.