Firman P03632

Generator · Performance Series. Specs from the manufacturer page (checked ).

Firman P03632
Photo: Firman

The Firman P03632 is a gasoline-powered inverter generator rated for 3650 W running and 4550 W starting watts. It has a 208cc engine, 120/240 volt output, and a 5-gallon steel fuel tank that the page says runs up to 14 hours at 1/4 load.

View at Firman →Sponsored link; we may earn a commission.
Running
3650W
Peak / surge
4550W
Fuel
gasoline
Weight
54.2kg
Warranty
3yr

Key features

What it is for

Specifications

Running watts3650 W
Peak / surge4550 W
Fuelgasoline
Tank18.9 L (5.0 gal)
AC output voltage120/240 volts
Weight54.2 kg (119.5 lb)
Warranty3 years

From the Firman page. Values the manufacturer does not publish are left out.

Similar inverter & portable generators

All Firman models →

Connection and wiring

Follow the diagrams in the Firman manual. Connecting to a home panel needs a transfer switch or interlock and a licensed electrician.

Error codes and troubleshooting

CodeMeaningWhat to doManual page
Circuit BreakersThe receptacles are protected by an AC circuit protector that trips if the generator is overloaded or an external short circuit occurs.Disconnect all electrical loads and determine the cause before using the generator again. If overloading caused the trip, reduce the load. Reset by pressing the protector button. Continuous tripping may damage the generator or equipment.8
Oil Warning Indicator LightIndicates the oil has fallen below the minimum level. The engine stops automatically and will not start until the proper amount of oil is in the crankcase.Check the oil level when this light turns on. Add the proper amount of engine oil to the crankcase before attempting to start the engine.8
Overload Indicator LightConnected devices have exceeded the generator's wattage or amperage capacity, or a power surge occurred. The AC Power light goes off, the engine keeps running, and power to the receptacles is cut.Keep the total power drawn from all receptacles within the nameplate rating.8
Circuit BreakerThe receptacles are protected by an AC circuit protector that trips if the generator is overloaded or an external short circuit occurs.Disconnect all electrical loads and find the cause before using the generator again. If overloading caused the trip, reduce the load. Reset by pressing the button on the protector. Continuous tripping may damage the generator or equipment.9
Output ReadyStays on during normal operation. Turns off when the generator is overloaded.—9
AC ResetThe inverter has entered a protective state and AC output is interrupted.Press the AC Reset Button to restore the output.12

6 of 13 codes. From the Firman manual. All 13 WH03242 / T09371 / H07553 / W03083 codes →

FAQ

Can the Firman P03632 start a sump pump or well pump?

Starting surge matters more than running watts: this unit is rated 4550 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.

Firman P03632View at Firman