9 codes from the official Allpowers manual (R600 V3.1), each with the manual page.

Applies to: Allpowers R600, Allpowers S2000 Pro.

CodeWhat it meansWhat to doServiceManual
E102
Charging low temperature protection
Charging is protected because the unit's internal temperature is too low for safe charging.Recovers automatically once the ambient temperature recovers. No user action is listed. owner p. 13
E103
Charging high temperature protection
Charging is protected because the unit's internal temperature is too high.Stop charging and check that the product's air vents are unobstructed. It recovers automatically after the temperature drops. owner p. 13
E104
Discharge low temperature protection
Discharge is protected because the unit's internal temperature is too low.Recovers automatically once the ambient temperature recovers. No user action is listed. owner p. 13
E105
Discharge high temperature protection
Discharge is protected because the unit's internal temperature is too high.Shut the unit down and let it stand for more than 2 hours. It recovers automatically after the product temperature drops. owner p. 13
E107
Total output (AC+DC) discharge overload
Combined AC and DC output exceeds the unit's protection limit.Remove part of the load, then manually turn the AC output back on. owner p. 13
E210
AC discharge overcurrent
AC output current exceeds the protection limit.Remove the load, then manually turn the AC output back on. owner p. 13
E211
AC discharge overload
AC output load exceeds the unit's rated output power.Remove the load and manually turn the AC output back on. Do not use the unit with devices that exceed its rated output power. owner p. 13
E212
AC discharge short circuit
A short circuit was detected on the AC output.Remove the load, repair the load circuit, then manually turn the AC output back on. owner p. 13
E301
MPPT input overvoltage
The solar panel voltage is above the unit's MPPT input range.Remove the solar panel. Do not charge the unit with a panel whose rated voltage exceeds the unit's input range. owner p. 13