Allpowers R600 / S2000 Pro error codes
9 codes from the official Allpowers manual (R600 V3.1), each with the manual page.
Applies to: Allpowers R600, Allpowers S2000 Pro.
| Code | What it means | What to do | Service | Manual |
|---|---|---|---|---|
| E102 Charging low temperature protection | Charging is protected because the unit's internal temperature is too low for safe charging. | Recovers automatically once the ambient temperature recovers. No user action is listed. | owner | p. 13 |
| E103 Charging high temperature protection | Charging is protected because the unit's internal temperature is too high. | Stop charging and check that the product's air vents are unobstructed. It recovers automatically after the temperature drops. | owner | p. 13 |
| E104 Discharge low temperature protection | Discharge is protected because the unit's internal temperature is too low. | Recovers automatically once the ambient temperature recovers. No user action is listed. | owner | p. 13 |
| E105 Discharge high temperature protection | Discharge is protected because the unit's internal temperature is too high. | Shut the unit down and let it stand for more than 2 hours. It recovers automatically after the product temperature drops. | owner | p. 13 |
| E107 Total output (AC+DC) discharge overload | Combined AC and DC output exceeds the unit's protection limit. | Remove part of the load, then manually turn the AC output back on. | owner | p. 13 |
| E210 AC discharge overcurrent | AC output current exceeds the protection limit. | Remove the load, then manually turn the AC output back on. | owner | p. 13 |
| E211 AC discharge overload | AC output load exceeds the unit's rated output power. | Remove the load and manually turn the AC output back on. Do not use the unit with devices that exceed its rated output power. | owner | p. 13 |
| E212 AC discharge short circuit | A short circuit was detected on the AC output. | Remove the load, repair the load circuit, then manually turn the AC output back on. | owner | p. 13 |
| E301 MPPT input overvoltage | The solar panel voltage is above the unit's MPPT input range. | Remove the solar panel. Do not charge the unit with a panel whose rated voltage exceeds the unit's input range. | owner | p. 13 |
Source: official Allpowers manual, read 2026-11-01. "Owner" means the manual lists steps you can take; "dealer" means it directs you to authorized service. Fuel, gas and electrical work on generators is for qualified technicians; follow the manual's safety section.