Power station · R600. Specs from the manufacturer page (checked ).

The Allpowers R600 is a 299 Wh portable power station with 600 W AC output and 1200 W surge, built on a LiFePO4 battery. It has two AC outlets, two USB-C and two USB-A ports, a 12V car port, and a 15W wireless charger. The page says it recharges from 0-99% in 1 hour from an AC wall outlet and switches to battery power within 10 ms during a grid outage.
Key features
- 2 AC outlets rated 600 W with 1200 W peak, 100-120V output
- 2 USB-C ports at 200 W max and 2 USB-A ports at 36 W max, plus a 120 W max car port and a 15 W wireless charger
- AC recharge from 0-99% in 1 hour at 400 W max input
- Solar input up to 220 W max (12-60V)
- UPS switchover within 10 ms when the grid fails
- Bluetooth app control with a range of 5-10 m
- LiFePO4 battery rated for 3500+ cycles to 80%, with BMS protection of voltage, current and temperature
What it is for
- RV camping
- Wilderness exploration
- UPS backup for desktop PC and file servers
Specifications
| Capacity | 299 Wh |
|---|---|
| Continuous output | 600 W |
| Peak / surge | 1200 W |
| Solar input | 220 W |
| Battery chemistry | LiFePO4 |
| Cycle life | 3500 cycles |
| AC charging | Recharge from 0-99% in 1 Hour |
| AC output voltage | 100-120V |
| Weight | 5.6 kg (12.3 lb) |
| Dimensions | 19.3 × 19.1 × 28.4 cm (7.6 × 7.5 × 11.2 in) |
| Warranty | 5 years |
From the Allpowers page. Values the manufacturer does not publish are left out.
What is in the box
- 1 x R600 power station
- 1 x AC charging cable
- 1 x R600 instruction manual
How long it runs common appliances
| Appliance | Watts | Runs? | Hours |
|---|---|---|---|
| Refrigerator (with freezer) | 120 W (600 start) | yes | 5.6 h |
| Chest freezer | 100 W (500 start) | yes | 7.9 h |
| CPAP (no humidifier) | 35 W (40 start) | yes | 6.8 h |
| Gas boiler (pump + controls) | 120 W (300 start) | yes | 3.9 h |
| Wi-Fi router + modem/ONU | 12 W | yes | 20 h |
| Starlink (standard dish) | 60 W (100 start) | yes | 3.9 h |
| TV 50" | 75 W | yes | 3.2 h |
| Sump pump 1/2 HP | 920 W (2150 start) | surge too high | — |
| Well pump 1/2 HP | 880 W (2000 start) | surge too high | — |
| Space heater 1500 W | 1500 W | surge too high | — |
Assumes 88 % inverter efficiency, 90 % usable capacity and typical duty cycles. Build your own list in the calculator.
Similar portable power stations
Jackery Explorer 300D
Bluetti Elite 30 V2
Westinghouse iGen300s
Jackery Explorer 240 v2
BougeRV JuiceGo
Vtoman Jump 600X
Bluetti EB3A
Allpowers R600 comparisons
- R600 vs Anker SOLIX C300X
- R600 vs Jackery Explorer 300D
- R600 vs Bluetti Elite 30 V2
- R600 vs Westinghouse iGen300s
- R600 vs Jackery Explorer 240 v2
- R600 vs BougeRV JuiceGo
All 17 comparisons
- R600 vs Vtoman Jump 600X
- R600 vs Bluetti EB3A
- R600 vs Bluetti Elite 30 mini
- R600 vs Dabbsson 300E
- R600 vs Goal Zero Yeti 300
- R600 vs Jackery Explorer 300 Plus
- R600 vs Pecron E300LFP
- R600 vs A-iPower GS350i
- R600 vs Aferiy P040 (Nomad400)
- R600 vs Marbero 296Wh Portable Power Station
- R600 vs Marbero 237Wh 300W Portable Power Station
Connection and wiring
Follow the diagrams in the Allpowers manual.
Open the Allpowers manual (PDF) →
Error codes and troubleshooting
| Code | Meaning | What to do | Manual page |
|---|---|---|---|
| E102 | Charging is protected because the unit's internal temperature is too low for safe charging. | Recovers automatically once the ambient temperature recovers. No user action is listed. | 13 |
| E103 | Charging is protected because the unit's internal temperature is too high. | Stop charging and check that the product's air vents are unobstructed. It recovers automatically after the temperature drops. | 13 |
| E104 | Discharge is protected because the unit's internal temperature is too low. | Recovers automatically once the ambient temperature recovers. No user action is listed. | 13 |
| E105 | Discharge is protected because the unit's internal temperature is too high. | Shut the unit down and let it stand for more than 2 hours. It recovers automatically after the product temperature drops. | 13 |
| E107 | Combined AC and DC output exceeds the unit's protection limit. | Remove part of the load, then manually turn the AC output back on. | 13 |
| E210 | AC output current exceeds the protection limit. | Remove the load, then manually turn the AC output back on. | 13 |
6 of 9 codes. From the Allpowers manual. All 9 R600 / S2000 Pro codes →
FAQ
How long will the Allpowers R600 run a refrigerator?
About 6 hours for a typical 120 W refrigerator that runs 35 % of the time, after inverter and depth-of-discharge losses.
Can the Allpowers R600 start a sump pump or well pump?
Starting surge matters more than running watts: this unit is rated 1200 W peak. That is below a typical 1/2 HP sump pump start (about 2150 W); check your pump label. Use the calculator with your exact pump.