10 codes from the official PowerSmart manual (3600W Inverter Generator Model HB5035), each with the manual page. For 2 of them the manual says to contact an authorized service dealer.

Applies to: PowerSmart PS5046CE, PowerSmart DB5035, PowerSmart DB5068.

CodeWhat it meansWhat to doServiceManual
Low-voltage
Low-voltage flashing
The multi-function meter flashes to indicate a low-voltage condition in the output.Press the MENU button for about 3 seconds to restore the display. owner p. 9
Maintenance
Maintenance indicator flashing
The indicator light flashes when the generator needs maintenance.Maintain the generator promptly when the maintenance indicator flashes. owner p. 9
Oil Warning Light (Yellow) Low oil level alarm. It prevents engine damage from insufficient crankcase oil by automatically shutting down the engine before oil falls to an unsafe level. The engine switch stays ON.Fill the engine oil to the upper limit (H) and check the level regularly. If the engine is restarted with low oil, the yellow light stays on and the engine will not run. Add oil, then restart. owner p. 9
Over-current
Over-current flashing
The multi-function meter flashes to indicate an over-current condition.Press the MENU button for about 3 seconds to restore the display. owner p. 9
Over-voltage
Over-voltage flashing
The multi-function meter flashes to indicate an over-voltage condition in the output.Press the MENU button for about 3 seconds to restore the display. owner p. 9
Short-circuit
Short-circuit flashing
The multi-function meter flashes when a short circuit has occurred.Remove all applied loads, then press the MENU button for about 3 seconds to restore the display. owner p. 9
AC Breaker
AC Breaker Button
Protects the 120V 20A AC output receptacle. The breaker pops out when this receptacle is overloaded.Reduce the load, then press the AC breaker button to reset. owner p. 10
DC Breaker
DC Breaker Button
Protects the 12V 8A DC output receptacle. The breaker pops out when this receptacle is overloaded.Reduce the load, then press the DC breaker button to reset. If DC overload occurs, remove the DC load, wait a few minutes, then reset the button. owner p. 10
Overload Indicator (Red) Output overload. If the red light stays on and the Running indicator goes off, the engine keeps running but produces no output power.Remove all loads and check whether connected devices exceed the recommended output or have faulty or shorted connections. Press MENU for about 3 seconds to reset, then restart the engine. If the overload returns, contact customer service. dealer p. 10
Overload
Overload indicator (red)
The red overload indicator lights when an electric motor starts. Normally the engine stops the overload within 4 seconds. Total connected power must not exceed the generator's rated power.Reduce the loads and press the reset button to restore output. If the indicator does not go out within 4 seconds, call customer service at 1-872-314-0005 (Mon-Fri 9am-5pm EST) or email [email protected]. dealer p. 11

Source: official PowerSmart manual, read 2026-11-03. "Owner" means the manual lists steps you can take; "dealer" means it directs you to authorized service. Fuel, gas and electrical work on generators is for qualified technicians; follow the manual's safety section.