A-iPower XOS2300iD
Generator. Specs from the manufacturer page (checked ).

The A-iPower XOS2300iD is a dual fuel inverter generator that runs on gasoline or propane and produces 1800 running watts and 2300 starting watts on gasoline. On propane it rates 1600 running watts and 2000 starting watts, and its 0.9-gallon tank gives up to 9 hours of runtime at 25% load. It weighs 40.8 pounds and carries a 3-year limited warranty.
Key features
- Runs on gasoline, propane, or both; Fuel Sense Technology switches from propane to gasoline when propane is depleted or disconnected
- Gasoline output: 1800 W running, 2300 W starting; propane output: 1600 W running, 2000 W starting
- Pure sine wave output with less than 3% THD at full load and a digital inverter
- Runtime at 25% load: up to 9 hours on the 0.9-gallon tank, up to 24 hours on a 20-lb propane cylinder, up to 33 hours with Fuel Sense
- Outlets: one L5-30R 120V/30A, one 5-20R 120V 20A, one USB-A 3.6A, one USB-C 3A
- Recoil start engine with parallel output (parallel cables) and low-oil shutdown
- CO sensor with automatic shutdown; EPA certified and ANSI/PGMA G300 compliant
Specifications
| Running watts | 1800 W |
|---|---|
| Peak / surge | 2300 W |
| Fuel | dual-fuel |
| Tank | 3.4 L (0.9 gal) |
| Noise | 61 dB |
| CO shutoff | Yes |
| AC output voltage | 120 Volts |
| Weight | 18.5 kg (40.8 lb) |
| Dimensions | 49.0 × 26.9 × 47.0 cm (19.3 × 10.6 × 18.5 in) |
| Warranty | 3 years |
From the A-iPower page. Values the manufacturer does not publish are left out.
Similar inverter & portable generators
DuroMax XP2300iH
GenMax GM2200i
Honda EB2200i
Pulsar 2200W Dual Fuel Inverter
Pulsar G2319N
WEN 56225i
Westinghouse iGen2200
Connection and wiring
Follow the diagrams in the A-iPower manual. Connecting to a home panel needs a transfer switch or interlock and a licensed electrician.
Open the A-iPower manual (PDF) →
Error codes and troubleshooting
| Code | Meaning | What to do | Manual page |
|---|---|---|---|
| Oil Warning | Lights when engine oil falls below the safe operating level. The generator automatically shuts off the engine and will not restart until the proper amount of oil is in the crankcase. | Add the proper amount of oil to the crankcase. The engine will not start until the oil is at the proper level. | 10 |
| Overload | Lights when connected devices or a power surge exceed the generator's wattage or amperage capacity. The Output Ready LED turns off, the engine keeps running, and power to connected devices stops. | Remove all loads and stop the engine. Check for faulty or shorted connections. Restart the generator, then reconnect devices one at a time, letting it stabilize after each. Keep total connected wattage within the rated output power. | 10 |
From the A-iPower manual. All 2 SUA2300i / XOS2600i / GXS1700i / SC2500i codes →
FAQ
Can the A-iPower XOS2300iD start a sump pump or well pump?
Starting surge matters more than running watts: this unit is rated 2300 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.