Bluetti AC200PL
Power station. Specs from the manufacturer page (checked ).

The AC200PL is a 2304 Wh portable power station with 2400 W rated AC output. It uses a LiFePO4 battery rated for 3000+ cycles and can be controlled through the BLUETTI App over Bluetooth or WiFi.
Key features
- 2,400 W rated AC output; Power Lifting Mode in the BLUETTI App raises output to 3,600 W for power-hungry heating devices.
- TT-30 port for powering an RV directly.
- 2,400 W Turbo Charging: 80% in 1 hour and a full charge in 1.5 hours.
- Charges from AC outlets, solar panels, car charger, generator, or lead-acid batteries; maximum input is 2,400 W from AC and solar combined.
- UPS function with switching time within 20 ms.
- Pass-through charging allows charging and discharging at the same time.
- Compatible with B210P, B230 and B300 expansion batteries; the battery itself cannot be replaced by the user.
- Charge range 0-40°C (32-104°F); discharge range -20-40°C (-4-104°F). Not waterproof.
What it is for
- RV use
- home backup
Specifications
| Capacity | 2304 Wh |
|---|---|
| Continuous output | 2400 W |
| Solar input | 1200 W |
| Expandable | Yes |
| Battery chemistry | LiFePO4 |
| Cycle life | 3000 cycles |
| AC output voltage | 120V |
| Weight | 27.9 kg (61.5 lb) |
| Dimensions | 41.9 × 27.9 × 36.6 cm (16.5 × 11.0 × 14.4 in) |
From the Bluetti page. Values the manufacturer does not publish are left out.
How long it runs common appliances
| Appliance | Watts | Runs? | Hours |
|---|---|---|---|
| Refrigerator (with freezer) | 120 W (600 start) | yes | 43 h |
| Chest freezer | 100 W (500 start) | yes | 61 h |
| CPAP (no humidifier) | 35 W (40 start) | yes | 52 h |
| Gas boiler (pump + controls) | 120 W (300 start) | yes | 30 h |
| Wi-Fi router + modem/ONU | 12 W | yes | 6.3 days |
| Starlink (standard dish) | 60 W (100 start) | yes | 30 h |
| TV 50" | 75 W | yes | 24 h |
| Sump pump 1/2 HP | 920 W (2150 start) | yes | 2.0 h |
| Well pump 1/2 HP | 880 W (2000 start) | yes | 2.1 h |
| Space heater 1500 W | 1500 W | yes | 1.7 h |
Assumes 88 % inverter efficiency, 90 % usable capacity and typical duty cycles. Build your own list in the calculator.
Similar portable power stations
Jackery Explorer 2000 v2
EcoFlow DELTA 3 Max
EcoFlow DELTA 3 Ultra Plus
DJI Power 2000
Anker SOLIX F3000
EcoFlow DELTA 3 Max Plus
Dabbsson 2000L
Bluetti AC200PL comparisons
- AC200PL vs EcoFlow DELTA 2 Max
- AC200PL vs Jackery Explorer 2000 v2
- AC200PL vs EcoFlow DELTA 3 Max
- AC200PL vs EcoFlow DELTA 3 Ultra Plus
- AC200PL vs DJI Power 2000
- AC200PL vs Anker SOLIX F3000
All 25 comparisons
- AC200PL vs EcoFlow DELTA 3 Max Plus
- AC200PL vs Dabbsson 2000L
- AC200PL vs EcoFlow DELTA 3 Ultra
- AC200PL vs Anker SOLIX F2600
- AC200PL vs Pecron E2400LFP
- AC200PL vs Allpowers R2500
- AC200PL vs BougeRV Rover 2000
- AC200PL vs Fossibot F2400
- AC200PL vs Dabbsson 3000L
- AC200PL vs Dabbsson DBS2100 Pro
- AC200PL vs Aferiy P280
- AC200PL vs Aferiy P300
- AC200PL vs Oukitel P2001 Plus
- AC200PL vs Oukitel P2001 Pro
- AC200PL vs Oukitel BP3000
- AC200PL vs Grecell 2400W Portable Power Station
- AC200PL vs Allpowers R2500 V2
- AC200PL vs EGO Nexus 1400W Portable Power Station (PST1400)
- AC200PL vs Oukitel BP2000
Connection and wiring
Follow the diagrams in the Bluetti manual.
Open the Bluetti manual (PDF) →
Error codes and troubleshooting
| Code | Meaning | What to do | Manual page |
|---|---|---|---|
| E004 | The output voltage is outside the expected range, or the grid connection is not proper. | Ensure the output voltage is within ±10% of the rated voltage or proper grid connection. | 21 |
| E016 | The internal fan is blocked, unplugged, or not functioning properly. | Check if the fan is blocked, unplugged, or not functioning properly. Ensure proper ventilation. | 21 |
| E117 | Grid oscillation has been detected at the grid input. | Disconnect the grid input and contact BLUETTI support for further assistance. Call service if it persists. | 21 |
| E074 | The battery management system (BMS) has detected a fault. The specific fault is shown in the mobile app. | Check the specific fault in the mobile app. If the battery is too hot or too cold, let the unit reach a suitable temperature before charging or using it (charging -15°C to 40°C; discharging -25°C to 40°C). | 22 |
| Others | Other errors not listed in the error code table. | Contact BLUETTI support for help. Call service if it persists. | 22 |
| E001 | The inverter is overloaded because the connected devices draw too much power. | Check whether the power consumption of your devices is too high. Reduce the load if necessary. | 23 |
6 of 23 codes. From the Bluetti manual. All 23 Elite 200 V2 / Apex 300 / Elite 100 V2 / AC70 codes →
FAQ
How long will the Bluetti AC200PL run a refrigerator?
About 43 hours for a typical 120 W refrigerator that runs 35 % of the time, after inverter and depth-of-discharge losses.
Can the Bluetti AC200PL start a sump pump or well pump?
Starting surge matters more than running watts: this unit is rated 2400 W output (no separate peak published). That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.