CodeWhat it meansWhat to doServiceManual
E004
Output failure
The output voltage is outside the expected range, or the grid connection is not proper.Ensure the output voltage is within ±10% of the rated voltage or proper grid connection. owner p. 21
E016
Fan failure
The internal fan is blocked, unplugged, or not functioning properly.Check if the fan is blocked, unplugged, or not functioning properly. Ensure proper ventilation. owner p. 21
E117
Grid oscillation
Grid oscillation has been detected at the grid input.Disconnect the grid input and contact BLUETTI support for further assistance. dealer p. 21
Others Other errors not listed in the error code table.Contact BLUETTI support for help. dealer p. 22
E001
Inverter overload
The inverter is overloaded because the connected devices draw too much power.Check whether the power consumption of your devices is too high. Reduce the load if necessary. owner p. 23
E002
Inverter overtemperature protection, AC output off
The inverter overheated and protection switched the AC output off.Wait for about 10 minutes until the unit cools down, then turn on the AC output again. owner p. 23
E003
Inverter short circuit
A short circuit has been detected at the inverter output.1. Check whether the power consumption of your devices is too high. 2. Check whether any of your electrical devices are causing a short circuit. owner p. 23
E026
Unit overload
Total unit output is overloaded.Check if the AC and DC output is above 2,800W. owner p. 23
E033
PV overvoltage
The solar (PV) input voltage is above the accepted range.Make sure the PV input voltage is within the range of 12V to 28VDC. owner p. 23
E039
PV overtemperature
The PV input has overheated.Wait for about 10 minutes until the unit cools down, then re-enable the PV input. owner p. 23
E065
DC output short circuit
A short circuit has been detected at the DC output.1. Check whether the power consumption of your devices is too high. 2. Check whether any of your electrical devices are causing a short circuit. owner p. 23
E067
DC output overcurrent
The DC output is drawing more current than allowed.Check whether the power consumption of your devices is too high. Reduce the load if necessary. owner p. 23
E068
DC output overtemperature
The DC output has overheated.Wait for about 10 minutes until the unit cools down, then restart your devices. owner p. 23
E085
Charging temperature too high
The unit's temperature is too high for charging.Wait for the unit to cool down before charging. owner p. 23
E086
Charging temperature too low
The unit's temperature is too low for charging.Make sure the unit is placed in an ambient temperature of 0°C to 40°C (32°F to 104°F). owner p. 23
E087
Discharging temperature too high
The unit's temperature is too high for discharging.Wait for the unit to cool down before discharging. owner p. 23
/
Others
An unspecified fault not covered by the listed error codes.Please contact BLUETTI support for assistance. dealer p. 24
E088
Discharging temperature too low
The unit's temperature is too low for discharging.Make sure the unit is placed in an ambient temperature of -20°C to 40°C (-4°F to 104°F). owner p. 24
E113
Grid overvoltage
The grid input voltage is too high.Check if the grid voltage is too high. Change the input source if necessary. owner p. 24
E114
Grid undervoltage
The grid input voltage is too low.Check if the grid voltage is too low. Change the input source if necessary. owner p. 24
E115
Grid overfrequency
The grid frequency is too high.Check if the grid frequency is too high. Contact your local power provider if necessary. owner p. 24
E116
Grid underfrequency
The grid frequency is too low.Check if the grid frequency is too low. Contact your local power provider if necessary. owner p. 24