Bluetti AC2P
Power station · Elite. Specs from the manufacturer page (checked ).

The BLUETTI AC2P is a 230.4 Wh portable power station with 300 W output, designed for travel and use at home gatherings. It has an AC outlet, USB-A and USB-C ports, a cigarette lighter port, and a DC solar input of 12V-28VDC. The manual states the unit is for off-grid use only and its AC output must not be connected to the grid.
Key features
- 230.4 Wh capacity and 300 W output
- AC outlet, USB-A port, USB-C port, and cigarette lighter port
- DC input for solar panels, 12V-28VDC; open-circuit voltage must not exceed 28V
- Solar charging cable and AC charging cable included
- Bluetooth connection and LCD display with ECO Mode, Power Lifting Mode, and Turbo Charging
- Shuts off automatically when AC and DC are both off for more than 1 minute
- Off-grid use only; AC output must not be connected to the grid
What it is for
- travel
- gatherings at home
Specifications
| Capacity | 1024 Wh |
|---|---|
| Continuous output | 1800 W |
| Peak / surge | 2700 W |
| Solar input | 1000 W |
| Battery chemistry | LiFePO4 |
| Cycle life | 4000 cycles |
| Noise | 30 dB |
| Weight | 11.5 kg (25.4 lb) |
| Dimensions | 32 × 21.5 × 25 cm (12.6 × 8.5 × 9.8 in) |
From the Bluetti page. Values the manufacturer does not publish are left out.
What is in the box
- AC Charging Cable
- Solar Charging Cable
- Grounding Screws (1)
- Car Charging Cable
- User Manual
- Warranty Card
How long it runs common appliances
| Appliance | Watts | Runs? | Hours |
|---|---|---|---|
| Refrigerator (with freezer) | 120 W (600 start) | yes | 19 h |
| Chest freezer | 100 W (500 start) | yes | 27 h |
| CPAP (no humidifier) | 35 W (40 start) | yes | 23 h |
| Gas boiler (pump + controls) | 120 W (300 start) | yes | 14 h |
| Wi-Fi router + modem/ONU | 12 W | yes | 68 h |
| Starlink (standard dish) | 60 W (100 start) | yes | 14 h |
| TV 50" | 75 W | yes | 11 h |
| Sump pump 1/2 HP | 920 W (2150 start) | yes | 0.9 h |
| Well pump 1/2 HP | 880 W (2000 start) | yes | 0.9 h |
| Space heater 1500 W | 1500 W | yes | 0.8 h |
Assumes 88 % inverter efficiency, 90 % usable capacity and typical duty cycles. Build your own list in the calculator.
Similar portable power stations
EcoFlow DELTA 3 Plus
Jackery Explorer 1000 Plus
EcoFlow DELTA 3
Anker SOLIX C800 Plus
Generac GB1000
EcoFlow DELTA 2
Westinghouse iGen1000s
Bluetti AC2P comparisons
- AC2P vs Anker SOLIX C1000 Gen 2
- AC2P vs EcoFlow DELTA 3 Plus
- AC2P vs Jackery Explorer 1000 Plus
- AC2P vs EcoFlow DELTA 3
- AC2P vs Anker SOLIX C800 Plus
- AC2P vs Generac GB1000
All 19 comparisons
- AC2P vs EcoFlow DELTA 2
- AC2P vs Westinghouse iGen1000s
- AC2P vs Vtoman FlashSpeed 1000
- AC2P vs Allpowers R1500 LITE
- AC2P vs Pecron E1000LFP
- AC2P vs Firman Zero E (E201001)
- AC2P vs Vtoman Jump 1500X
- AC2P vs Dabbsson 1000L
- AC2P vs Dabbsson 600L
- AC2P vs EcoFlow RIVER 2 Pro
- AC2P vs Yoshino B2000 SST
- AC2P vs Anker SOLIX C1000
- AC2P vs Allpowers P1800
Connection and wiring
Follow the diagrams in the Bluetti manual.
Open the Bluetti manual (PDF) →
Error codes and troubleshooting
| Code | Meaning | What to do | Manual page |
|---|---|---|---|
| E004 | The output voltage is outside the expected range, or the grid connection is not proper. | Ensure the output voltage is within ±10% of the rated voltage or proper grid connection. | 21 |
| E016 | The internal fan is blocked, unplugged, or not functioning properly. | Check if the fan is blocked, unplugged, or not functioning properly. Ensure proper ventilation. | 21 |
| E117 | Grid oscillation has been detected at the grid input. | Disconnect the grid input and contact BLUETTI support for further assistance. Call service if it persists. | 21 |
| E074 | The battery management system (BMS) has detected a fault. The specific fault is shown in the mobile app. | Check the specific fault in the mobile app. If the battery is too hot or too cold, let the unit reach a suitable temperature before charging or using it (charging -15°C to 40°C; discharging -25°C to 40°C). | 22 |
| Others | Other errors not listed in the error code table. | Contact BLUETTI support for help. Call service if it persists. | 22 |
| E001 | The inverter is overloaded because the connected devices draw too much power. | Check whether the power consumption of your devices is too high. Reduce the load if necessary. | 23 |
6 of 23 codes. From the Bluetti manual. All 23 Elite 200 V2 / Apex 300 / Elite 100 V2 / AC70 codes →
FAQ
How long will the Bluetti AC2P run a refrigerator?
About 19 hours for a typical 120 W refrigerator that runs 35 % of the time, after inverter and depth-of-discharge losses.
Can the Bluetti AC2P start a sump pump or well pump?
Starting surge matters more than running watts: this unit is rated 2700 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.