Blackout Sizer Calculator
EN
Home›Portable Power Stations›Bluetti›Apex 300

Bluetti Apex 300

Power station · Apex. Specs from the manufacturer page (checked ).

Bluetti Apex 300
Photo: Bluetti

The Bluetti Apex 300 is a 2764.8 Wh portable power station with 3840 W output and 7680 W lifting power. It powers 120V and 240V devices at the same time and offers 0ms UPS switchover for backup. The LiFePO4 battery is rated for up to 6,000 cycles with 80% capacity retention.

Check on Amazon →Sponsored link; we may earn a commission.
Capacity
2764.8Wh
Continuous
3840W
Peak / surge
7680W
Solar input
4000W
Chemistry
LiFePO4
Cycles
6000
Expandable
Yes

Key features

What it is for

Specifications

Capacity2764.8 Wh
Continuous output3840 W
Peak / surge7680 W
Solar input4000 W
ExpandableYes
Battery chemistryLiFePO4
Cycle life6000 cycles
AC output voltage120V/240V

From the Bluetti page. Values the manufacturer does not publish are left out.

What is in the box

How long it runs common appliances

ApplianceWattsRuns?Hours
Refrigerator (with freezer)120 W (600 start)yes52 h
Chest freezer100 W (500 start)yes3.0 days
CPAP (no humidifier)35 W (40 start)yes63 h
Gas boiler (pump + controls)120 W (300 start)yes36 h
Wi-Fi router + modem/ONU12 Wyes7.6 days
Starlink (standard dish)60 W (100 start)yes36 h
TV 50"75 Wyes29 h
Sump pump 1/2 HP920 W (2150 start)yes2.4 h
Well pump 1/2 HP880 W (2000 start)yes2.5 h
Space heater 1500 W1500 Wyes2.1 h

Assumes 88 % inverter efficiency, 90 % usable capacity and typical duty cycles. Build your own list in the calculator.

Similar portable power stations

Bluetti Apex 300 comparisons

All 11 comparisons

On our lists

Best power stations for a space heaterBest LiFePO4 power stationsBest expandable power stationsBest power stations for solar charging

All Bluetti models →

Connection and wiring

Follow the diagrams in the Bluetti manual.

Error codes and troubleshooting

CodeMeaningWhat to doManual page
E004The output voltage is outside the expected range, or the grid connection is not proper.Ensure the output voltage is within ±10% of the rated voltage or proper grid connection.21
E016The internal fan is blocked, unplugged, or not functioning properly.Check if the fan is blocked, unplugged, or not functioning properly. Ensure proper ventilation.21
E117Grid oscillation has been detected at the grid input.Disconnect the grid input and contact BLUETTI support for further assistance. Call service if it persists.21
OthersOther errors not listed in the error code table.Contact BLUETTI support for help. Call service if it persists.22
E001The inverter is overloaded because the connected devices draw too much power.Check whether the power consumption of your devices is too high. Reduce the load if necessary.23
E002The inverter overheated and protection switched the AC output off.Wait for about 10 minutes until the unit cools down, then turn on the AC output again.23

6 of 22 codes. From the Bluetti manual. All 22 Elite 200 V2 / Apex 300 / Elite 100 V2 / AC70 codes →

FAQ

How long will the Bluetti Apex 300 run a refrigerator?

About 52 hours for a typical 120 W refrigerator that runs 35 % of the time, after inverter and depth-of-discharge losses.

Can the Bluetti Apex 300 start a sump pump or well pump?

Starting surge matters more than running watts: this unit is rated 7680 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.

Bluetti Apex 300Check on Amazon