Bluetti Elite 100 mini
Power station · Elite. Specs from the manufacturer page (checked ).

The Bluetti Elite 100 mini is a 1,004.8 Wh portable power station with 700 W total output. It has 9 ports: 3 AC outlets, 6 DC outputs, and dual USB-C ports rated 140 W and 65 W. Its UltraCell LFP battery is rated for 6,000+ charge cycles.
Key features
- 9 ports: 3 AC outlets, 6 DC outputs, and USB-C ports at 140W and 65W
- Total output not to exceed 700W
- Recharge through 700W AC, up to 350W solar, a 12V/24V vehicle, or BLUETTI Charger 1
- 80% in 90 minutes at home
- Built-in 10ms UPS
- Built-in LED light bar runs up to 264 hours
- Portable fridge runtime 34.4 hours; Wi-Fi runtime 39.2 hours
- UltraCell LFP battery rated for 6,000+ cycles with 50 built-in safety protections
What it is for
- camping
- road trips and van life
- mobile or outdoor work
- short-term home backup during outages
Specifications
| Capacity | 1004.8 Wh |
|---|---|
| Continuous output | 700 W |
| Solar input | 350 W |
| Battery chemistry | LiFePO4 |
| Cycle life | 6000 cycles |
| AC charging | 80% in 90 minutes at home |
| Weight | 10.7 kg (23.6 lb) |
| Dimensions | 9.3 × 8.5 inches (footprint) |
From the Bluetti page. Values the manufacturer does not publish are left out.
What is in the box
- AC Charging Cable x1
- Car Charging Cable x1
- User Manual x1
How long it runs common appliances
| Appliance | Watts | Runs? | Hours |
|---|---|---|---|
| Refrigerator (with freezer) | 120 W (600 start) | yes | 19 h |
| Chest freezer | 100 W (500 start) | yes | 27 h |
| CPAP (no humidifier) | 35 W (40 start) | yes | 23 h |
| Gas boiler (pump + controls) | 120 W (300 start) | yes | 13 h |
| Wi-Fi router + modem/ONU | 12 W | yes | 66 h |
| Starlink (standard dish) | 60 W (100 start) | yes | 13 h |
| TV 50" | 75 W | yes | 11 h |
| Sump pump 1/2 HP | 920 W (2150 start) | surge too high | — |
| Well pump 1/2 HP | 880 W (2000 start) | surge too high | — |
| Space heater 1500 W | 1500 W | surge too high | — |
Assumes 88 % inverter efficiency, 90 % usable capacity and typical duty cycles. Build your own list in the calculator.
Similar portable power stations
EcoFlow DELTA 3 Classic
EcoFlow DELTA 3 Plus
Jackery Explorer 1000 Plus
EcoFlow DELTA 3
Anker SOLIX C800 Plus
Generac GB1000
EcoFlow DELTA 2
Bluetti Elite 100 mini comparisons
- Elite 100 mini vs Anker SOLIX C1000 Gen 2
- Elite 100 mini vs EcoFlow DELTA 3 Classic
- Elite 100 mini vs EcoFlow DELTA 3 Plus
- Elite 100 mini vs Jackery Explorer 1000 Plus
- Elite 100 mini vs EcoFlow DELTA 3
- Elite 100 mini vs Anker SOLIX C800 Plus
All 20 comparisons
- Elite 100 mini vs Generac GB1000
- Elite 100 mini vs EcoFlow DELTA 2
- Elite 100 mini vs DJI Power 1000 Mini
- Elite 100 mini vs Vtoman FlashSpeed 1000
- Elite 100 mini vs Allpowers R1500 LITE
- Elite 100 mini vs Pecron E1000LFP
- Elite 100 mini vs Vtoman Jump 1500X
- Elite 100 mini vs Dabbsson 1000L
- Elite 100 mini vs Dabbsson 600L
- Elite 100 mini vs EcoFlow RIVER 2 Pro
- Elite 100 mini vs Yoshino B2000 SST
- Elite 100 mini vs Anker SOLIX C1000
- Elite 100 mini vs Oukitel P1000 PLUS
- Elite 100 mini vs Allpowers P1800
Connection and wiring
Follow the diagrams in the Bluetti manual.
Open the Bluetti manual (PDF) →
Error codes and troubleshooting
| Code | Meaning | What to do | Manual page |
|---|---|---|---|
| E004 | The output voltage is outside the expected range, or the grid connection is not proper. | Ensure the output voltage is within ±10% of the rated voltage or proper grid connection. | 21 |
| E016 | The internal fan is blocked, unplugged, or not functioning properly. | Check if the fan is blocked, unplugged, or not functioning properly. Ensure proper ventilation. | 21 |
| E117 | Grid oscillation has been detected at the grid input. | Disconnect the grid input and contact BLUETTI support for further assistance. Call service if it persists. | 21 |
| E074 | The battery management system (BMS) has detected a fault. The specific fault is shown in the mobile app. | Check the specific fault in the mobile app. If the battery is too hot or too cold, let the unit reach a suitable temperature before charging or using it (charging -15°C to 40°C; discharging -25°C to 40°C). | 22 |
| Others | Other errors not listed in the error code table. | Contact BLUETTI support for help. Call service if it persists. | 22 |
| E001 | The inverter is overloaded because the connected devices draw too much power. | Check whether the power consumption of your devices is too high. Reduce the load if necessary. | 23 |
6 of 23 codes. From the Bluetti manual. All 23 Elite 200 V2 / Apex 300 / Elite 100 V2 / AC70 codes →
FAQ
How long will the Bluetti Elite 100 mini run a refrigerator?
About 19 hours for a typical 120 W refrigerator that runs 35 % of the time, after inverter and depth-of-discharge losses.
Can the Bluetti Elite 100 mini start a sump pump or well pump?
Starting surge matters more than running watts: this unit is rated 700 W output (no separate peak published). That is below a typical 1/2 HP sump pump start (about 2150 W); check your pump label. Use the calculator with your exact pump.