Bluetti Elite 100 V2
Power station. Specs from the manufacturer page (checked ).

The Bluetti Elite 100 V2 is a 1,024 Wh portable power station with 1,800 W output and 2,700 W lifting power, built on LiFePO₄ cells rated for over 4,000 cycles. It weighs 11.5 kg (25 lbs) and recharges to 80% in 45 minutes from AC.
Key features
- 11 ports for running appliances, rated at 1,800 W output with 2,700 W lifting power
- Reaches 80% in 45 mins with 1,200W AC TurboBoost charging
- Solar input up to 1,000 W with built-in MPPT, full charge in 70 mins
- Car charging is stated as 6× faster than standard car chargers
- UPS switchover in 10 ms for sensitive devices
- Rated 4,000+ cycles to 80% original capacity
- Operates at 30 dB under light loads
- WiFi/Bluetooth connectivity with the BLUETTI App, including low-battery and full-charge alerts and Power Memory Mode
What it is for
- Home backup during power outages
- Camping
- RV power
- Travel
Specifications
| Capacity | 1024 Wh |
|---|---|
| Continuous output | 1800 W |
| Peak / surge | 2700 W |
| Solar input | 1000 W |
| Battery chemistry | LiFePO4 |
| Cycle life | 4000 cycles |
| Noise | 30 dB |
| AC charging | Reaches 80% in 45 mins |
| AC output voltage | 120V |
| Weight | 11.5 kg (25.4 lb) |
| Dimensions | 32 × 21.5 × 25 cm (12.6 × 8.5 × 9.8 in) |
From the Bluetti page. Values the manufacturer does not publish are left out.
What is in the box
- Elite 100 V2 x1
- User Manual x1
- Grounding Screw x1
How long it runs common appliances
| Appliance | Watts | Runs? | Hours |
|---|---|---|---|
| Refrigerator (with freezer) | 120 W (600 start) | yes | 19 h |
| Chest freezer | 100 W (500 start) | yes | 27 h |
| CPAP (no humidifier) | 35 W (40 start) | yes | 23 h |
| Gas boiler (pump + controls) | 120 W (300 start) | yes | 14 h |
| Wi-Fi router + modem/ONU | 12 W | yes | 68 h |
| Starlink (standard dish) | 60 W (100 start) | yes | 14 h |
| TV 50" | 75 W | yes | 11 h |
| Sump pump 1/2 HP | 920 W (2150 start) | yes | 0.9 h |
| Well pump 1/2 HP | 880 W (2000 start) | yes | 0.9 h |
| Space heater 1500 W | 1500 W | yes | 0.8 h |
Assumes 88 % inverter efficiency, 90 % usable capacity and typical duty cycles. Build your own list in the calculator.
Similar portable power stations
EcoFlow DELTA 3 Plus
Jackery Explorer 1000 Plus
EcoFlow DELTA 3
Anker SOLIX C800 Plus
Generac GB1000
EcoFlow DELTA 2
Westinghouse iGen1000s
Bluetti Elite 100 V2 comparisons
- Elite 100 V2 vs Anker SOLIX C1000 Gen 2
- Elite 100 V2 vs EcoFlow DELTA 3 Plus
- Elite 100 V2 vs Jackery Explorer 1000 Plus
- Elite 100 V2 vs EcoFlow DELTA 3
- Elite 100 V2 vs Anker SOLIX C800 Plus
- Elite 100 V2 vs Generac GB1000
All 19 comparisons
- Elite 100 V2 vs EcoFlow DELTA 2
- Elite 100 V2 vs Westinghouse iGen1000s
- Elite 100 V2 vs Vtoman FlashSpeed 1000
- Elite 100 V2 vs Allpowers R1500 LITE
- Elite 100 V2 vs Pecron E1000LFP
- Elite 100 V2 vs Firman Zero E (E201001)
- Elite 100 V2 vs Vtoman Jump 1500X
- Elite 100 V2 vs Dabbsson 1000L
- Elite 100 V2 vs Dabbsson 600L
- Elite 100 V2 vs EcoFlow RIVER 2 Pro
- Elite 100 V2 vs Yoshino B2000 SST
- Elite 100 V2 vs Anker SOLIX C1000
- Elite 100 V2 vs Allpowers P1800
On our lists
Connection and wiring
Follow the diagrams in the Bluetti manual.
Open the Bluetti manual (PDF) →
Error codes and troubleshooting
| Code | Meaning | What to do | Manual page |
|---|---|---|---|
| E004 | The output voltage is outside the expected range, or the grid connection is not proper. | Ensure the output voltage is within ±10% of the rated voltage or proper grid connection. | 21 |
| E016 | The internal fan is blocked, unplugged, or not functioning properly. | Check if the fan is blocked, unplugged, or not functioning properly. Ensure proper ventilation. | 21 |
| E117 | Grid oscillation has been detected at the grid input. | Disconnect the grid input and contact BLUETTI support for further assistance. Call service if it persists. | 21 |
| E074 | The battery management system (BMS) has detected a fault. The specific fault is shown in the mobile app. | Check the specific fault in the mobile app. If the battery is too hot or too cold, let the unit reach a suitable temperature before charging or using it (charging -15°C to 40°C; discharging -25°C to 40°C). | 22 |
| Others | Other errors not listed in the error code table. | Contact BLUETTI support for help. Call service if it persists. | 22 |
| E001 | The inverter is overloaded because the connected devices draw too much power. | Check whether the power consumption of your devices is too high. Reduce the load if necessary. | 23 |
6 of 23 codes. From the Bluetti manual. All 23 Elite 200 V2 / Apex 300 / Elite 100 V2 / AC70 codes →
FAQ
How long will the Bluetti Elite 100 V2 run a refrigerator?
About 19 hours for a typical 120 W refrigerator that runs 35 % of the time, after inverter and depth-of-discharge losses.
Can the Bluetti Elite 100 V2 start a sump pump or well pump?
Starting surge matters more than running watts: this unit is rated 2700 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.