Firman P08013

Generator · Performance Series. Specs from the manufacturer page (checked ).

Firman P08013
Photo: Firman

The Firman P08013 is a gasoline inverter generator rated at 8000 running watts and 10,000 starting watts. It has a 439cc engine, an 8-gallon tank, and 120/240 volt outlets, and the page lists 12 hours of run time at 50% load.

View at Firman →Sponsored link; we may earn a commission.
Running
8000W
Peak / surge
10000W
Fuel
gasoline
Run time @50 %
12h
Noise
82dB
CO shutoff
Yes
Weight
102.5kg
Warranty
3yr

Key features

Specifications

Running watts8000 W
Peak / surge10000 W
Fuelgasoline
Tank30.3 L (8.0 gal)
Run time at 50 % load12 h
Noise82 dB
CO shutoffYes
AC output voltage120/240 volts
Weight102.5 kg (226.0 lb)
Warranty3 years

From the Firman page. Values the manufacturer does not publish are left out.

Similar inverter & portable generators

All Firman models →

Connection and wiring

Follow the diagrams in the Firman manual. Connecting to a home panel needs a transfer switch or interlock and a licensed electrician.

Error codes and troubleshooting

CodeMeaningWhat to doManual page
Circuit BreakersThe receptacles are protected by an AC circuit protector that trips if the generator is overloaded or an external short circuit occurs.Disconnect all electrical loads and determine the cause before using the generator again. If overloading caused the trip, reduce the load. Reset by pressing the protector button. Continuous tripping may damage the generator or equipment.8
Oil Warning Indicator LightIndicates the oil has fallen below the minimum level. The engine stops automatically and will not start until the proper amount of oil is in the crankcase.Check the oil level when this light turns on. Add the proper amount of engine oil to the crankcase before attempting to start the engine.8
Overload Indicator LightConnected devices have exceeded the generator's wattage or amperage capacity, or a power surge occurred. The AC Power light goes off, the engine keeps running, and power to the receptacles is cut.Keep the total power drawn from all receptacles within the nameplate rating.8
Circuit BreakerThe receptacles are protected by an AC circuit protector that trips if the generator is overloaded or an external short circuit occurs.Disconnect all electrical loads and find the cause before using the generator again. If overloading caused the trip, reduce the load. Reset by pressing the button on the protector. Continuous tripping may damage the generator or equipment.9
Output ReadyStays on during normal operation. Turns off when the generator is overloaded.—9
AC ResetThe inverter has entered a protective state and AC output is interrupted.Press the AC Reset Button to restore the output.12

6 of 13 codes. From the Firman manual. All 13 WH03242 / T09371 / H07553 / W03083 codes →

FAQ

How long does the Firman P08013 run on a tank?

The maker rates it at 12 hours at 50 % load (about 4,000 W) on a 8.0-gal tank. A light load such as a refrigerator and lights runs longer; a full load runs shorter.

Can the Firman P08013 start a sump pump or well pump?

Starting surge matters more than running watts: this unit is rated 10000 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.