Blackout Sizer Calculator
EN
Home›Portable Power Stations›Pecron›E1500LFP

Pecron E1500LFP

Power station · E1500LFP. Specs from the manufacturer page (checked ).

Pecron E1500LFP
Photo: Pecron

The Pecron E1500LFP is a 1536 Wh portable power station with 2200 W rated output and 4400 W peak output (10 ms). It uses a LiFePO4 battery, can be expanded up to 7680 Wh with two EP3000-48V units, and can be controlled by app over Wi-Fi or Bluetooth.

Check on Amazon →Sponsored link; we may earn a commission.
Capacity
1536Wh
Continuous
2200W
Peak / surge
4400W
Solar input
1000W
Chemistry
LiFePO4
Expandable
Yes
Weight
17.4kg

Key features

What it is for

Specifications

Capacity1536 Wh
Continuous output2200 W
Peak / surge4400 W
Solar input1000 W
ExpandableYes
Battery chemistryLiFePO4
AC output voltage100V~120V
Weight17.4 kg (38.4 lb)
Dimensions37.6 × 23.6 × 30.5 cm (14.8 × 9.3 × 12.0 in)

From the Pecron page. Values the manufacturer does not publish are left out.

How long it runs common appliances

ApplianceWattsRuns?Hours
Refrigerator (with freezer)120 W (600 start)yes29 h
Chest freezer100 W (500 start)yes41 h
CPAP (no humidifier)35 W (40 start)yes35 h
Gas boiler (pump + controls)120 W (300 start)yes20 h
Wi-Fi router + modem/ONU12 Wyes4.2 days
Starlink (standard dish)60 W (100 start)yes20 h
TV 50"75 Wyes16 h
Sump pump 1/2 HP920 W (2150 start)yes1.3 h
Well pump 1/2 HP880 W (2000 start)yes1.4 h
Space heater 1500 W1500 Wyes1.2 h

Assumes 88 % inverter efficiency, 90 % usable capacity and typical duty cycles. Build your own list in the calculator.

Similar portable power stations

Pecron E1500LFP comparisons

All 28 comparisons

All Pecron models →

Connection and wiring

Follow the diagrams in the Pecron manual.

Open the Pecron manual (PDF) →

Error codes and troubleshooting

CodeMeaningWhat to doManual page
AC Overload AlarmThe AC overload alarm icon flashes when connected devices draw more than 2200 W. The unit stops supplying AC power.Keep AC loads under 2200 W, since the unit can power most devices below that consumption. Reduce or disconnect the excess load. The page does not give further steps.5
Temperature AlarmThe high-temperature alarm icon flashes after long high-power output in hot conditions, indicating the inverter is overheated. AC output is turned off.The page gives no explicit remedy. The operating range is -20 to 45°C, so keep the unit within that range. Allow it to cool before resuming use.5

From the Pecron manual. All 2 E2400LFP / E1500LFP codes →

FAQ

How long will the Pecron E1500LFP run a refrigerator?

About 29 hours for a typical 120 W refrigerator that runs 35 % of the time, after inverter and depth-of-discharge losses.

Can the Pecron E1500LFP start a sump pump or well pump?

Starting surge matters more than running watts: this unit is rated 4400 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.

Pecron E1500LFPCheck on Amazon