Pulsar PG105TiSRCO
Generator · Pulsar. Specs from the manufacturer page (checked ).

The Pulsar PG105TiSRCO is a tri-fuel inverter generator with 8,500 W rated running power and 10,500 W peak power. It runs on gasoline, propane, or natural gas and provides 120V and 240V output. The page lists a 7-gallon fuel tank and a noise rating of 63 dB at half load.
Key features
- Runs on gasoline, propane, or natural gas
- Rated power: 8500W (gasoline), 8000W (LPG), 6800W (natural gas)
- Peak power: 10500W (gasoline), 9500W (LPG), 8400W (natural gas)
- Outlets: USB-A, USB-C, four 120V 5-20R, one 120V/240V 30A L14-30R, one 120V/240V 50A 14-50R
- Automatic Transfer Switch outlet for home backup power
- Runs up to 10.5 continuous hours at half load on a 7-gallon fuel tank
- Digital display for runtime, voltage, and frequency
- Parallel-ready: two units can be combined to double output
- Start options: recoil, electric, and remote
- Safety: carbon monoxide detection, voltage regulation, and low oil shutdown
What it is for
- home backup
- RV
- job site
Specifications
| Running watts | 8500 W |
|---|---|
| Peak / surge | 10500 W |
| Fuel | tri-fuel |
| Tank | 26.5 L (7.0 gal) |
| Run time at 50 % load | 10.5 h |
| Noise | 63 dB |
| CO shutoff | Yes |
| AC output voltage | 120V/240V |
From the Pulsar page. Values the manufacturer does not publish are left out.
What is in the box
- motor oil
- funnel
- spark plug wrench
- propane hose
- natural gas hose
- starter battery
- remote
Similar inverter & portable generators
WEN TF1050iX
WEN DF1100T
WEN DF1100X
Champion 11000-Watt Dual Fuel Home Backup Inverter
Champion 11000-Watt Remote Start Tri-Fuel Inverter
DuroStar DS10000EH
Firman H08051
Connection and wiring
Follow the diagrams in the Pulsar manual. Connecting to a home panel needs a transfer switch or interlock and a licensed electrician.
Error codes and troubleshooting
| Code | Meaning | What to do | Manual page |
|---|---|---|---|
| RED | Carbon monoxide has accumulated around the generator and the unit shut off due to a CO hazard. The red light flashes for at least five minutes after shut-off. Automatic shutoff with a flashing red light means the generator was improperly located. | Move the generator to an open outdoor area far from occupied spaces, with the exhaust pointed away. Once it is in a safe area, it can be restarted. Introduce fresh air and ventilate the area where the generator shut down. | 4 |
| YELLOW | A CO Sentry system fault occurred. The generator shut down automatically, and the yellow light flashes for at least five minutes after the fault. | The generator can be restarted, but it may continue to shut off. | 4 |
| CO | Detects the presence of carbon monoxide and may shut down the unit automatically for safety. | The manual gives no specific reset step for this indicator. If dizziness, weakness, or nausea occur, turn the unit off, move to fresh air, and seek medical attention. Operate only outdoors, away from enclosed spaces. | 5 |
| Low Oil LED | The engine oil level has fallen below the safe operating limit (270 ml or less). The engine shuts off automatically and cannot restart until the proper oil amount is added. | Add the appropriate oil until the level is at the proper mark. SAE 10W-30 is recommended for general use. Do not run the engine with too little oil. | 14 |
| OVERLOAD | The total load on the outlets exceeds the generator's running power. If the light turns on and the generator stops producing power, it has been overloaded. The light may flash briefly when a large device starts. | Turn off and disconnect all electrical devices and stop the engine. Compare device requirements to the generator rating and reduce connected wattage if necessary. Check and reset any tripped circuit breakers, then restart and reconnect devices without overloading. | 14 |
| LOW OIL | The engine oil level is too low. The engine shuts off automatically when the oil falls below a critical level. | Add the appropriate oil, SAE 10w-30 recommended for general use, until the oil is at the proper level. The engine cannot be restarted until the proper amount of oil has been added. | 15 |
6 of 8 codes. From the Pulsar manual. All 8 PG12000BCO / PG7750BCO / PG6580BCO / PG105TiSRCO codes →
FAQ
How long does the Pulsar PG105TiSRCO run on a tank?
The maker rates it at 10.5 hours at 50 % load (about 4,250 W) on a 7.0-gal tank. A light load such as a refrigerator and lights runs longer; a full load runs shorter.
Can the Pulsar PG105TiSRCO start a sump pump or well pump?
Starting surge matters more than running watts: this unit is rated 10500 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.