Blackout Sizer Calculator
EN
Home›Inverter & Portable Generators›Pulsar›PG13000BRCO

Pulsar PG13000BRCO

Generator. Specs from the manufacturer page (checked ).

Pulsar PG13000BRCO
Photo: Pulsar

The Pulsar PG13000BRCO is a dual-fuel portable generator that runs on gasoline or propane. On gasoline it provides 13,000 W peak and 10,200 W rated output, and on propane it provides 11,500 W peak and 9,200 W rated output.

View at Pulsar →Sponsored link; we may earn a commission.
Running
10200W
Peak / surge
13000W
Fuel
dual-fuel
Run time @50 %
9.5h

Key features

What it is for

Specifications

Running watts10200 W
Peak / surge13000 W
Fueldual-fuel
Tank35.96 L (9.5 gal)
Run time at 50 % load9.5 h
AC output voltage120V/240V

From the Pulsar page. Values the manufacturer does not publish are left out.

What is in the box

Similar inverter & portable generators

All Pulsar models →

Connection and wiring

Follow the diagrams in the Pulsar manual. Connecting to a home panel needs a transfer switch or interlock and a licensed electrician.

Open the Pulsar manual (PDF) →

Error codes and troubleshooting

CodeMeaningWhat to doManual page
REDCarbon monoxide has accumulated around the generator and the unit shut off due to a CO hazard. The red light flashes for at least five minutes after shut-off. Automatic shutoff with a flashing red light means the generator was improperly located.Move the generator to an open outdoor area far from occupied spaces, with the exhaust pointed away. Once it is in a safe area, it can be restarted. Introduce fresh air and ventilate the area where the generator shut down.4
YELLOWA CO Sentry system fault occurred. The generator shut down automatically, and the yellow light flashes for at least five minutes after the fault.The generator can be restarted, but it may continue to shut off.4
CODetects the presence of carbon monoxide and may shut down the unit automatically for safety.The manual gives no specific reset step for this indicator. If dizziness, weakness, or nausea occur, turn the unit off, move to fresh air, and seek medical attention. Operate only outdoors, away from enclosed spaces.5
Low Oil LEDThe engine oil level has fallen below the safe operating limit (270 ml or less). The engine shuts off automatically and cannot restart until the proper oil amount is added.Add the appropriate oil until the level is at the proper mark. SAE 10W-30 is recommended for general use. Do not run the engine with too little oil.14
OVERLOADThe total load on the outlets exceeds the generator's running power. If the light turns on and the generator stops producing power, it has been overloaded. The light may flash briefly when a large device starts.Turn off and disconnect all electrical devices and stop the engine. Compare device requirements to the generator rating and reduce connected wattage if necessary. Check and reset any tripped circuit breakers, then restart and reconnect devices without overloading.14
LOW OILThe engine oil level is too low. The engine shuts off automatically when the oil falls below a critical level.Add the appropriate oil, SAE 10w-30 recommended for general use, until the oil is at the proper level. The engine cannot be restarted until the proper amount of oil has been added.15

6 of 8 codes. From the Pulsar manual. All 8 PG12000BCO / PG7750BCO / PG6580BCO / PG105TiSRCO codes →

FAQ

How long does the Pulsar PG13000BRCO run on a tank?

The maker rates it at 9.5 hours at 50 % load (about 5,100 W) on a 9.5-gal tank. A light load such as a refrigerator and lights runs longer; a full load runs shorter.

Can the Pulsar PG13000BRCO start a sump pump or well pump?

Starting surge matters more than running watts: this unit is rated 13000 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.

Pulsar PG13000BRCOView at Pulsar