Pulsar PG4000BiSRCO
Generator. Specs from the manufacturer page (checked ).

The Pulsar PG4000BiSRCO is a dual-fuel inverter generator rated at 3200 running watts and 4000 peak watts on gasoline. It also runs on propane, which the page rates at 2800 running watts and 3600 peak watts. It has a 1.6-gallon fuel tank that provides up to 6 hours at half load, weighs 54 lbs, and includes CO Sentry, which shuts the generator off if harmful carbon monoxide is detected.
Key features
- Dual fuel: gasoline gives 4000 peak / 3200 running watts; propane gives 3600 peak / 2800 running watts
- 141cc OHV engine
- Start options: remote start, electric push-button start, and recoil start
- 1.6-gallon fuel tank, up to 6 hours of continuous power at half load
- Outlets: two 120V outlets, one 120V RV outlet (TT-30R), USB-A and USB-C ports, and a 12V DC outlet
- Parallel capable: two generators can be linked into one
- CO Sentry automatically shuts off the generator if harmful carbon monoxide levels are detected
- Less than 3% total harmonic distortion
What it is for
- Home backup
- Camping
- Tailgating
- RV use
Specifications
| Running watts | 3200 W |
|---|---|
| Peak / surge | 4000 W |
| Fuel | dual-fuel |
| Tank | 6 L (1.6 gal) |
| Run time at 50 % load | 6 h |
| CO shutoff | Yes |
| AC output voltage | 120V |
| Weight | 24.5 kg (54.0 lb) |
From the Pulsar page. Values the manufacturer does not publish are left out.
Similar inverter & portable generators
EcoFlow Smart Generator (Dual Fuel)
GenMax GM3500iAED
GenMax GM3500Xi
PowerSmart 4000W Inverter Generator
PowerSmart DB5068
WEN 56400iX
WEN DF400i
Connection and wiring
Follow the diagrams in the Pulsar manual. Connecting to a home panel needs a transfer switch or interlock and a licensed electrician.
Error codes and troubleshooting
| Code | Meaning | What to do | Manual page |
|---|---|---|---|
| RED | Carbon monoxide has accumulated around the generator and the unit shut off due to a CO hazard. The red light flashes for at least five minutes after shut-off. Automatic shutoff with a flashing red light means the generator was improperly located. | Move the generator to an open outdoor area far from occupied spaces, with the exhaust pointed away. Once it is in a safe area, it can be restarted. Introduce fresh air and ventilate the area where the generator shut down. | 4 |
| YELLOW | A CO Sentry system fault occurred. The generator shut down automatically, and the yellow light flashes for at least five minutes after the fault. | The generator can be restarted, but it may continue to shut off. | 4 |
| CO | Detects the presence of carbon monoxide and may shut down the unit automatically for safety. | The manual gives no specific reset step for this indicator. If dizziness, weakness, or nausea occur, turn the unit off, move to fresh air, and seek medical attention. Operate only outdoors, away from enclosed spaces. | 5 |
| Low Oil LED | The engine oil level has fallen below the safe operating limit (270 ml or less). The engine shuts off automatically and cannot restart until the proper oil amount is added. | Add the appropriate oil until the level is at the proper mark. SAE 10W-30 is recommended for general use. Do not run the engine with too little oil. | 14 |
| OVERLOAD | The total load on the outlets exceeds the generator's running power. If the light turns on and the generator stops producing power, it has been overloaded. The light may flash briefly when a large device starts. | Turn off and disconnect all electrical devices and stop the engine. Compare device requirements to the generator rating and reduce connected wattage if necessary. Check and reset any tripped circuit breakers, then restart and reconnect devices without overloading. | 14 |
| LOW OIL | The engine oil level is too low. The engine shuts off automatically when the oil falls below a critical level. | Add the appropriate oil, SAE 10w-30 recommended for general use, until the oil is at the proper level. The engine cannot be restarted until the proper amount of oil has been added. | 15 |
6 of 8 codes. From the Pulsar manual. All 8 PG12000BCO / PG7750BCO / PG6580BCO / PG105TiSRCO codes →
FAQ
How long does the Pulsar PG4000BiSRCO run on a tank?
The maker rates it at 6 hours at 50 % load (about 1,600 W) on a 1.6-gal tank. A light load such as a refrigerator and lights runs longer; a full load runs shorter.
Can the Pulsar PG4000BiSRCO start a sump pump or well pump?
Starting surge matters more than running watts: this unit is rated 4000 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.