Pulsar PG6580BCO
Generator. Specs from the manufacturer page (checked ).

The Pulsar PG6580BCO is a dual-fuel portable generator rated at 5,300 W running and 6,580 W peak on gasoline. On propane it is rated at 4,750 W running and 5,922 W peak.
View at Pulsar →Sponsored link; we may earn a commission.
Running
5300W
Peak / surge
6580W
Fuel
dual-fuel
CO shutoff
Yes
Key features
- Gasoline output: 6,580 W peak and 5,300 W rated; propane output: 5,922 W peak and 4,750 W rated
- Switch & Go Technology switches between fuel sources while the generator is still running
- Two 120 V AC outlets, one 120/240 V twist-lock outlet, and one 30 A RV outlet
- 5.3 gal fuel tank gives up to 10 hours of continuous operation at half load on gasoline
- Recoil start; 274 cc, 4-stroke, OHV, air-cooled engine
- Low oil shutdown and carbon monoxide detection
- Digital meter shows voltage, frequency, run time, total hours, and maintenance
- Fold-down handles and 12-inch never-flat wheels
What it is for
- backup power during outages
- job sites
- outdoor adventures
Specifications
| Running watts | 5300 W |
|---|---|
| Peak / surge | 6580 W |
| Fuel | dual-fuel |
| Tank | 20 L (5.3 gal) |
| CO shutoff | Yes |
| AC output voltage | 120/240V |
From the Pulsar page. Values the manufacturer does not publish are left out.
What is in the box
- Propane hose for dual-fuel operation
Similar inverter & portable generators
5300 W, gasoline
Westinghouse WGen5300cv
5300 W, gasoline
Westinghouse WGen5300DF
5300 W, dual-fuel
Westinghouse WGen5300DFc
5300 W, dual-fuel
GenMax GM6000iED
5250 W, dual-fuel
Champion 5500-Watt Dual Fuel
5500 W, dual-fuel
Honda EM6500SXK2
5500 W, gas
Honda EU7000iS
5500 W, gas
Connection and wiring
Follow the diagrams in the Pulsar manual. Connecting to a home panel needs a transfer switch or interlock and a licensed electrician.
Open the Pulsar manual (PDF) →
Error codes and troubleshooting
| Code | Meaning | What to do | Manual page |
|---|---|---|---|
| RED | Carbon monoxide has accumulated around the generator and the unit shut off due to a CO hazard. The red light flashes for at least five minutes after shut-off. Automatic shutoff with a flashing red light means the generator was improperly located. | Move the generator to an open outdoor area far from occupied spaces, with the exhaust pointed away. Once it is in a safe area, it can be restarted. Introduce fresh air and ventilate the area where the generator shut down. | 4 |
| YELLOW | A CO Sentry system fault occurred. The generator shut down automatically, and the yellow light flashes for at least five minutes after the fault. | The generator can be restarted, but it may continue to shut off. | 4 |
| CO | Detects the presence of carbon monoxide and may shut down the unit automatically for safety. | The manual gives no specific reset step for this indicator. If dizziness, weakness, or nausea occur, turn the unit off, move to fresh air, and seek medical attention. Operate only outdoors, away from enclosed spaces. | 5 |
| Low Oil LED | The engine oil level has fallen below the safe operating limit (270 ml or less). The engine shuts off automatically and cannot restart until the proper oil amount is added. | Add the appropriate oil until the level is at the proper mark. SAE 10W-30 is recommended for general use. Do not run the engine with too little oil. | 14 |
| OVERLOAD | The total load on the outlets exceeds the generator's running power. If the light turns on and the generator stops producing power, it has been overloaded. The light may flash briefly when a large device starts. | Turn off and disconnect all electrical devices and stop the engine. Compare device requirements to the generator rating and reduce connected wattage if necessary. Check and reset any tripped circuit breakers, then restart and reconnect devices without overloading. | 14 |
| LOW OIL | The engine oil level is too low. The engine shuts off automatically when the oil falls below a critical level. | Add the appropriate oil, SAE 10w-30 recommended for general use, until the oil is at the proper level. The engine cannot be restarted until the proper amount of oil has been added. | 15 |
6 of 8 codes. From the Pulsar manual. All 8 PG12000BCO / PG7750BCO / PG6580BCO / PG105TiSRCO codes →
FAQ
Can the Pulsar PG6580BCO start a sump pump or well pump?
Starting surge matters more than running watts: this unit is rated 6580 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.