Pulsar PGD105TiSCO
Generator. Specs from the manufacturer page (checked ).

The Pulsar PGD105TiSCO is a tri-fuel inverter generator that runs on gasoline, propane, or natural gas. On gasoline it is rated at 8,500 running watts and 10,500 peak watts, while propane gives 8,000 running watts and natural gas gives 6,800 running watts.
Key features
- Runs on gasoline, propane, or natural gas. Gasoline: 10,500 peak / 8,500 running watts; propane: 9,500 peak / 8,000 running watts; natural gas: 8,400 peak / 6,800 running watts
- Outlets: 1 USB-A, 1 USB-C, 4 GFCI 120V 5-20R, 1 120V/240V L14-30R, 1 120V/240V 14-50R
- 458cc OHV engine, EPA and CARB approved
- 7 gallon fuel tank supports up to 9 hours of continuous operation at half load
- Volume rated at 62 dB
- Digital control center displays hours, voltage, load, and frequency
- Parallel capable: combine two generators to double output
- Remote start fob and electric start; includes carbon monoxide detection and low oil shutoff
What it is for
- residential
- mobile
- work applications
Specifications
| Running watts | 8500 W |
|---|---|
| Peak / surge | 10500 W |
| Fuel | tri-fuel |
| Tank | 26.5 L (7.0 gal) |
| Run time at 50 % load | 9 h |
| CO shutoff | Yes |
| AC output voltage | 120V/240V |
From the Pulsar page. Values the manufacturer does not publish are left out.
What is in the box
- Remote fob
- Electric start battery
- Propane and Natural Gas hose with regulator
- 10W-30 motor oil
- Spark plug wrench
- Screwdriver
Similar inverter & portable generators
WEN DF1100T
Champion 9000-Watt Tri Fuel Inverter (201176)
DuroMax XP13000HX
Champion 11500-Watt Tri Fuel
Generac XT8500EFI
WEN TF1050iX
WEN DF1100X
Pulsar PGD105TiSCO comparisons
- PGD105TiSCO vs Westinghouse WGen9500DFc
- PGD105TiSCO vs WEN DF1100T
- PGD105TiSCO vs Champion 9000-Watt Tri Fuel Inverter (201176)
- PGD105TiSCO vs DuroMax XP13000HX
- PGD105TiSCO vs Champion 11500-Watt Tri Fuel
Connection and wiring
Follow the diagrams in the Pulsar manual. Connecting to a home panel needs a transfer switch or interlock and a licensed electrician.
Error codes and troubleshooting
| Code | Meaning | What to do | Manual page |
|---|---|---|---|
| RED | Carbon monoxide has accumulated around the generator and the unit shut off due to a CO hazard. The red light flashes for at least five minutes after shut-off. Automatic shutoff with a flashing red light means the generator was improperly located. | Move the generator to an open outdoor area far from occupied spaces, with the exhaust pointed away. Once it is in a safe area, it can be restarted. Introduce fresh air and ventilate the area where the generator shut down. | 4 |
| YELLOW | A CO Sentry system fault occurred. The generator shut down automatically, and the yellow light flashes for at least five minutes after the fault. | The generator can be restarted, but it may continue to shut off. | 4 |
| CO | Detects the presence of carbon monoxide and may shut down the unit automatically for safety. | The manual gives no specific reset step for this indicator. If dizziness, weakness, or nausea occur, turn the unit off, move to fresh air, and seek medical attention. Operate only outdoors, away from enclosed spaces. | 5 |
| Low Oil LED | The engine oil level has fallen below the safe operating limit (270 ml or less). The engine shuts off automatically and cannot restart until the proper oil amount is added. | Add the appropriate oil until the level is at the proper mark. SAE 10W-30 is recommended for general use. Do not run the engine with too little oil. | 14 |
| OVERLOAD | The total load on the outlets exceeds the generator's running power. If the light turns on and the generator stops producing power, it has been overloaded. The light may flash briefly when a large device starts. | Turn off and disconnect all electrical devices and stop the engine. Compare device requirements to the generator rating and reduce connected wattage if necessary. Check and reset any tripped circuit breakers, then restart and reconnect devices without overloading. | 14 |
| LOW OIL | The engine oil level is too low. The engine shuts off automatically when the oil falls below a critical level. | Add the appropriate oil, SAE 10w-30 recommended for general use, until the oil is at the proper level. The engine cannot be restarted until the proper amount of oil has been added. | 15 |
6 of 8 codes. From the Pulsar manual. All 8 PG12000BCO / PG7750BCO / PG6580BCO / PG105TiSRCO codes →
FAQ
How long does the Pulsar PGD105TiSCO run on a tank?
The maker rates it at 9 hours at 50 % load (about 4,250 W) on a 7.0-gal tank. A light load such as a refrigerator and lights runs longer; a full load runs shorter.
Can the Pulsar PGD105TiSCO start a sump pump or well pump?
Starting surge matters more than running watts: this unit is rated 10500 W peak. That covers a typical 1/2 HP sump pump (about 2150 W to start). Use the calculator with your exact pump.