WEN DF402iX

Generator · DF402iX RV-Ready. Specs from the manufacturer page (checked ).

WEN DF402iX
Photo: WEN

The WEN DF402iX is a dual-fuel open frame inverter generator with a 212cc engine, rated for 3500 running watts and 4000 surge watts on gasoline. On propane it produces 3200 running watts and 3600 surge watts. It includes the WEN Watchdog CO Shutdown Sensor, which automatically turns the generator off if dangerous carbon monoxide levels are detected.

Check on Amazon →Sponsored link; we may earn a commission.
Running
3500W
Peak / surge
4000W
Fuel
dual-fuel
CO shutoff
Yes
Warranty
2yr

Key features

What it is for

Specifications

Running watts3500 W
Peak / surge4000 W
Fueldual-fuel
CO shutoffYes
AC output voltage120V
Warranty2 years

From the WEN page. Values the manufacturer does not publish are left out.

Similar inverter & portable generators

WEN DF402iX comparisons

All WEN models →

Connection and wiring

Follow the diagrams in the WEN manual. Connecting to a home panel needs a transfer switch or interlock and a licensed electrician.

Error codes and troubleshooting

CodeMeaningWhat to doManual page
OverloadGenerator was overloaded by too much drawn wattage. The overload reset button activates and cuts output within 3 to 16 seconds, depending on load.Turn off and disconnect electrical devices until the overload light turns off. Wait about five minutes, then press the activated reset button. If no power after reset, turn off and disconnect all devices and restart the generator.23
Flashes 1xVoltage at the alternator is too low. There is no electrical output.Check for loose connections. Call 1-800-232-1195 for assistance. Call service if it persists.24
Flashes 2xEngine speed is too low. There is no electrical output.Check carburetor and stepper motor. Ensure Eco-Mode is OFF. Have the generator serviced; call 1-800-232-1195 for assistance. Call service if it persists.24
Flashes 3xInverter temperature is too high. There is no electrical output.Turn the generator off and let it cool fully for 1 to 2 hours before restarting.24
Flashes 5xVoltage at the alternator is too high. There is no electrical output.Have the generator serviced; call 1-800-232-1195 for assistance. Call service if it persists.24
Flashes 6xGenerator exceeded rated output and cut off power to protect itself. There is no electrical output.Turn OFF and disconnect loads. Press the RESET button on the panel. Reduce the load on the generator.24

6 of 7 codes. From the WEN manual. All 7 DF875iX / DF402iX / GN875iX / GN625iX codes →