CodeWhat it meansWhat to doServiceManual
AC High Temperature Protection The product has overheated on the AC output side and protection has shut off AC output.No action is required. Normal operation resumes automatically after the product cools down. owner p. 21
AC Output Overload Protection The AC output is overloaded and its protection has shut off AC output.Remove the overloaded device, then restart the product. Normal operation resumes automatically after the overloaded device is removed. owner p. 21
DC Output Overload Protection The DC outlet is overloaded and its protection has shut off DC output.Remove the device connected to the DC outlet. Normal operation resumes automatically after the device is removed. owner p. 21
Fan Blockage The product's cooling fan is blocked, which can cause overheating.Check whether the fan is blocked and clear any obstruction at the fan inlet or outlet. Normal operation resumes automatically after the product cools down. owner p. 21
High Temperature Charge Protection The battery is too hot to charge safely, so charging has been stopped by protection.No action is required. Charging resumes automatically after the battery cools down. owner p. 21
High Temperature Discharge Protection The battery is too hot to discharge safely, so power supply has been cut by protection.No action is required. Power supply resumes automatically after the battery cools down. owner p. 21
Low Temperature Charge Protection The battery is too cold to charge safely, so charging has been stopped by protection.No action is required. Charging resumes automatically after battery temperature rises above -10℃ (14℉). owner p. 21
Low Temperature Discharge Protection The battery is too cold to discharge safely, so power supply has been cut by protection.No action is required. Power supply resumes automatically after battery temperature rises above -20℃ (-4℉). owner p. 21
USB-A Overload Protection The USB-A output has been overloaded and its protection has activated, stopping output on that port.Remove the electrical device connected to the USB-A port. Normal operation resumes once the device is removed. owner p. 21