Dabbsson 1000L
Power station. Specs from the manufacturer page (checked ).

The Dabbsson 1000L is a 1008 Wh portable power station with 1200 W AC output and 1800 W in Power-Boost Mode. It accepts 600 W of solar input and can charge from 0-80% in 50 minutes from a wall outlet.
Key features
- 8 ports: 2× AC (1200W), 1× USB-C (100W), 1× USB-C (30W), 2× USB-A (30W), 1× Car Charge (126W), 1× DC5521
- Power-Boost Mode raises output from 1200W to 1800W for appliances with heating elements rated 1800W or lower
- AC input 120V, 1000W; 0-80% in 50 mins with DabFlash Charging
- Solar input 12-60V 21A Max, 600W Max; full charge in 2.4 hours with MPPT Technology
- AC and solar dual charging combined at 1400W
- 12V/10A car charging
- 15ms UPS for uninterrupted operation
- Smart control and monitoring via the Dabbsson App
- 4000 cycles to 80% capacity
What it is for
- everyday outdoor use
- blackout backup
Specifications
| Capacity | 1008 Wh |
|---|---|
| Continuous output | 1200 W |
| Solar input | 600 W |
| Cycle life | 4000 cycles |
| AC charging | Charge from 0-80% in just 50 mins |
| Weight | 10.6 kg (23.4 lb) |
| Dimensions | 39.0 × 18.8 × 24.0 cm (15.4 × 7.4 × 9.4 in) |
| Warranty | 3 years |
From the Dabbsson page. Values the manufacturer does not publish are left out.
What is in the box
- 1000L
- AC Charging Cable
- Car Charging Cable
- User Manual
- Warranty Card
How long it runs common appliances
| Appliance | Watts | Runs? | Hours |
|---|---|---|---|
| Refrigerator (with freezer) | 120 W (600 start) | yes | 19 h |
| Chest freezer | 100 W (500 start) | yes | 27 h |
| CPAP (no humidifier) | 35 W (40 start) | yes | 23 h |
| Gas boiler (pump + controls) | 120 W (300 start) | yes | 13 h |
| Wi-Fi router + modem/ONU | 12 W | yes | 67 h |
| Starlink (standard dish) | 60 W (100 start) | yes | 13 h |
| TV 50" | 75 W | yes | 11 h |
| Sump pump 1/2 HP | 920 W (2150 start) | surge too high | — |
| Well pump 1/2 HP | 880 W (2000 start) | surge too high | — |
| Space heater 1500 W | 1500 W | surge too high | — |
Assumes 88 % inverter efficiency, 90 % usable capacity and typical duty cycles. Build your own list in the calculator.
Similar portable power stations
EcoFlow DELTA 3 Classic
EcoFlow DELTA 3 Plus
Bluetti Elite 100 V2
Bluetti AC70
Jackery Explorer 1000 Plus
EcoFlow DELTA 3
Anker SOLIX C800 Plus
Dabbsson 1000L comparisons
- 1000L vs Jackery Explorer 1000 v2
- 1000L vs EcoFlow DELTA 3 Classic
- 1000L vs EcoFlow DELTA 3 Plus
- 1000L vs Bluetti Elite 100 V2
- 1000L vs Bluetti AC70
- 1000L vs Jackery Explorer 1000 Plus
All 24 comparisons
- 1000L vs EcoFlow DELTA 3
- 1000L vs Anker SOLIX C800 Plus
- 1000L vs Generac GB1000
- 1000L vs EcoFlow DELTA 2
- 1000L vs Bluetti AC180
- 1000L vs Jackery HomePower 1000 v2
- 1000L vs Westinghouse iGen1000s
- 1000L vs Vtoman FlashSpeed 1000
- 1000L vs Bluetti Elite 100 mini
- 1000L vs Allpowers R1500 LITE
- 1000L vs Pecron E1000LFP
- 1000L vs Vtoman Jump 1500X
- 1000L vs EcoFlow RIVER 2 Pro
- 1000L vs Bluetti AC2P
- 1000L vs Yoshino B2000 SST
- 1000L vs Anker SOLIX C1000
- 1000L vs Oukitel P1000 PLUS
- 1000L vs Allpowers P1800
Connection and wiring
Follow the diagrams in the Dabbsson manual.
Open the Dabbsson manual (PDF) →
Error codes and troubleshooting
| Code | Meaning | What to do | Manual page |
|---|---|---|---|
| AC High Temperature Protection | The product has overheated on the AC output side and protection has shut off AC output. | No action is required. Normal operation resumes automatically after the product cools down. | 21 |
| AC Output Overload Protection | The AC output is overloaded and its protection has shut off AC output. | Remove the overloaded device, then restart the product. Normal operation resumes automatically after the overloaded device is removed. | 21 |
| DC Output Overload Protection | The DC outlet is overloaded and its protection has shut off DC output. | Remove the device connected to the DC outlet. Normal operation resumes automatically after the device is removed. | 21 |
| Fan Blockage | The product's cooling fan is blocked, which can cause overheating. | Check whether the fan is blocked and clear any obstruction at the fan inlet or outlet. Normal operation resumes automatically after the product cools down. | 21 |
| High Temperature Charge Protection | The battery is too hot to charge safely, so charging has been stopped by protection. | No action is required. Charging resumes automatically after the battery cools down. | 21 |
| High Temperature Discharge Protection | The battery is too hot to discharge safely, so power supply has been cut by protection. | No action is required. Power supply resumes automatically after the battery cools down. | 21 |
6 of 9 codes. From the Dabbsson manual. All 9 1000L / 600L / 3000L / DBS2100 Pro codes →
FAQ
How long will the Dabbsson 1000L run a refrigerator?
About 19 hours for a typical 120 W refrigerator that runs 35 % of the time, after inverter and depth-of-discharge losses.
Can the Dabbsson 1000L start a sump pump or well pump?
Starting surge matters more than running watts: this unit is rated 1200 W output (no separate peak published). That is below a typical 1/2 HP sump pump start (about 2150 W); check your pump label. Use the calculator with your exact pump.